Water Treatment Unit
/
PID-3401
Chemical dosing
100%
SVG
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. Hypochlorite tank is shaded and vented outdoors. Keep
away from acids.
2. Dosing pump speeds are set from the control system.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
WATER TREATMENT UNIT
PIPING AND INSTRUMENT DIAGRAM: CHEMICAL DOSING
DRAWING NO.
PID-3401
SHEET / REV
4 OF 4 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
TK-3401
COAGULANT TANK
D
P-3401
COAGULANT DOSING PUMP
TK-3402
HYPOCHLORITE TANK
D
P-3402
HYPOCHLORITE DOSING
PUMP
B/L
CHEMICAL UNLOADING
2"-CH-3403-P10
1"-CH-3404-P10
PID-3101
TO M-3101
1"-CH-3401-P10
B/L
CHEMICAL UNLOADING
2"-CH-3405-P10
1"-CH-3406-P10
PID-3301
TO TK-3301
1"-CH-3402-P10
LT
3401
LI
3401
SC
3401
LT
3402
LI
3402
SC
3402