E-1401
Air aftercooler
Heat exchanger
Open on drawing PID-1401
Data sheet
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. The compressor package has its own control panel, not
shown. PIC-1402 sets its discharge pressure.
2. Air goes to both enzyme reactors and the catalytic
oxidation reactor.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
SUGAR TO HYDROGEN PEROXIDE
PIPING AND INSTRUMENT DIAGRAM: PROCESS AIR SUPPLY
DRAWING NO.
PID-1401
SHEET / REV
4 OF 15 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
F-1401
INLET AIR FILTER
M
K-1401
PROCESS AIR COMPRESSOR
E-1401
AIR AFTERCOOLER
V-1401
AIR KNOCKOUT DRUM
V-1402
AIR RECEIVER
B/L
ATMOSPHERE
16"-PA-1401-C10
16"-PA-1402-C10
12"-PA-1403-S10
12"-PA-1404-S10
12"-PA-1405-S10
PID-1501
TO R-1501
8"-PA-1406-S10
PID-1601
TO R-1601
8"-PA-1407-S10
PID-2101
TO R-2101
4"-PA-1408-S10
B/L
DRAIN
S
LV-1401
1"-WW-1401-C10
PID-2401
FROM H-2401
6"-CWS-2406-C10
PID-2401
TO H-2402
TV-1404
6"-CWR-2416-C10
PDT
1401
PT
1402
PIC
1402
4.5 barg
TT
1404
TIC
1404
35 C
LSH
1401
LY
1401
PT
1405
Design and operating data
Area
85 m2
Duty
610 kW
Tube
Air
Type
Shell and tube
Shell
Cooling water
Material
SS316L
Connections
Flows in
12"-PA-1403-S10
from K-1401
6"-CWS-2406-C10
from H-2401
Flows out
12"-PA-1404-S10
to V-1401
6"-CWR-2416-C10
to H-2402
Documents
E-1401 data sheet
Notes
Save note
History
No changes recorded.