Sugar to Hydrogen Peroxide
/
PID-1301
Enzyme and caustic dosing
100%
SVG
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. Enzyme dose follows feed rate (ratio set in the
control system).
2. Caustic dose is set by the pH controllers on the
reactors (AIC-1502, AIC-1602).
3. Recovered enzyme from the ultrafiltration unit returns
to TK-1301.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
SUGAR TO HYDROGEN PEROXIDE
PIPING AND INSTRUMENT DIAGRAM: ENZYME AND CAUSTIC
DOSING
DRAWING NO.
PID-1301
SHEET / REV
3 OF 15 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
M
TK-1301
ENZYME MAKE-UP TANK
D
P-1301
ENZYME DOSING PUMP
TK-1302
CAUSTIC DAY TANK
D
P-1302
CAUSTIC DOSING PUMP
B/L
DEMIN WATER
1"-DW-1301-S10
B/L
ENZYME TOTES
1"-CH-1302-S10
PID-1701
FROM M-1701
2"-PR-1704-S10
1"-PR-1303-S10
PID-1501
TO R-1501
1"-PR-1304-S10
B/L
CAUSTIC UNLOADING
2"-CH-1305-P10
1"-CH-1306-P10
PID-1501
TO R-1501
1"-CH-1307-P10
LT
1301
LI
1301
SC
1301
LT
1302
LI
1302
SC
1302
Scroll to zoom · drag to move · click anything to inspect