Plants
/
Sugar to Hydrogen Peroxide
/ E-1903
E-1903
Product cooler
Heat exchanger
Open on drawing PID-1901
Data sheet
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. Column runs under deep vacuum so the peroxide stays
below 60 C. Never run the reboiler dry.
2. Recovered water goes back to the utility system for
reuse.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
SUGAR TO HYDROGEN PEROXIDE
PIPING AND INSTRUMENT DIAGRAM: PEROXIDE
CONCENTRATION (DISTILLATION)
DRAWING NO.
PID-1901
SHEET / REV
9 OF 15 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
C-1901
PEROXIDE DISTILLATION
COLUMN
E-1901
OVERHEAD CONDENSER
V-1901
REFLUX DRUM
P-1901
REFLUX PUMP
E-1902
REBOILER
E-1903
PRODUCT COOLER
PID-1801
FROM P-1802
FV-1901
2"-PR-1805-S10
14"-PG-1901-A10
3"-PR-1902-A10
3"-PR-1903-A10
FV-1904
2"-PR-1904-A10
PID-2501
TO H-2502
LV-1901
2"-PW-1905-S10
4"-PR-1906-A10
6"-PG-1907-A10
LV-1902
1"-PR-1908-A10
PID-2001
TO TK-2001
1"-PR-1909-A10
PID-2001
TO TK-2002
1"-PR-2001-A10
PID-2501
FROM H-2501
TV-1902
3"-LS-2503-C10
PID-2501
TO H-2502
2"-SC-2513-C10
PID-2401
FROM H-2401
6"-CWS-2407-C10
PID-2401
TO H-2402
6"-CWR-2417-C10
PT
1901
PIC
1901
0.07 bara
TT
1902
TIC
1902
LT
1901
LIC
1901
FT
1904
FIC
1904
AT
1908
40-60 wt% H2O2
AIC
1908
50 wt%
FT
1901
FIC
1901
Design and operating data
Area
8 m2
Duty
80 kW
Type
Plate
Material
SS316L
Connections
Flows in
1"-PR-1908-A10
from C-1901
Flows out
1"-PR-1909-A10
to TK-2001
1"-PR-2001-A10
to TK-2002
Documents
E-1903 data sheet
Notes
Save note
History
No changes recorded.