Plants
/
Sugar to Hydrogen Peroxide
/ EV-2201
EV-2201
Acid concentrator
Evaporator
Open on drawing PID-2201
Data sheet
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. Concentration is set by product density DIC-2201,
which trims steam.
2. Crystalliser cooled slowly to grow large,
easy-to-filter crystals.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
SUGAR TO HYDROGEN PEROXIDE
PIPING AND INSTRUMENT DIAGRAM: ACID CONCENTRATION
AND CRYSTALLISATION
DRAWING NO.
PID-2201
SHEET / REV
12 OF 15 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
EV-2201
ACID CONCENTRATOR
E-2201
CONCENTRATOR CONDENSER
P-2201
CONCENTRATE PUMP
M
CR-2201
COOLING CRYSTALLISER
P-2202
SLURRY PUMP
PID-2101
FROM V-2101
2"-PR-2107-S10
PID-2301
FROM P-2301
3"-PR-2303-S10
12"-PG-2201-S10
B/L
WASTEWATER TREATMENT
2"-WW-2202-S10
2"-PR-2203-S10
FV-2204
2"-PR-2204-S10
3"-PR-2205-S10
PID-2301
TO CF-2301
2"-PR-2206-S10
PID-2501
FROM H-2501
FV-2201
3"-LS-2505-C10
PID-2501
TO H-2502
2"-SC-2515-C10
PID-2401
FROM H-2401
TV-2205
3"-CWS-2409-C10
PID-2401
TO H-2402
3"-CWR-2419-C10
PT
2201
PIC
2201
0.2 bara
DT
2201
1.1-1.5 kg/L
DIC
2201
LT
2201
LIC
2201
TT
2205
TIC
2205
15 C
Design and operating data
Duty
1.6 MW
Type
Forced circulation
Material
SS316L
Operating pressure
0.2 bara
Connections
Flows in
2"-PR-2107-S10
from V-2101
3"-PR-2303-S10
from P-2301
3"-LS-2505-C10
from H-2501
Flows out
12"-PG-2201-S10
to E-2201
2"-PR-2203-S10
to P-2201
2"-SC-2515-C10
to H-2502
Instruments
PT-2201
Pressure transmitter
Documents
EV-2201 data sheet
Notes
Save note
History