M-1701

Ultrafiltration unit
Membrane unit
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D E E F F NOTES 1. Enzyme is held back by the membrane and returned to the make-up tank. 2. Clean in place (CIP) connections are not shown. INSTRUMENT SYMBOLS Field mounted Control system (DCS), operator can see it Electric signal Main process line Utility / secondary line ENTHRA LABS DEMO DRAWING SUGAR TO HYDROGEN PEROXIDE PIPING AND INSTRUMENT DIAGRAM: ENZYME RECOVERY (ULTRAFILTRATION) DRAWING NO. PID-1701 SHEET / REV 7 OF 15 REV 0 SCALE: NONE DATE: 2026-11-24 FICTIONAL PLANT FOR DEMONSTRATION. NOT FOR CONSTRUCTION. M TK-1701 BROTH HOLD TANK P-1701 UF FEED PUMP M-1701 ULTRAFILTRATION UNIT PID-1601 FROM P-1601 3"-PR-1602-S10 4"-PR-1701-S10 3"-PR-1702-S10 PID-1801 TO E-1801 FV-1703 3"-PR-1703-S10 PID-1301 TO TK-1301 PV-1704 2"-PR-1704-S10 LT 1701 LIC 1701 PDT 1701 0-3 bar PDI 1701 FT 1703 FIC 1703 PT 1704 PIC 1704 2.5 barg
Design and operating data
Area420 m2
TypeSpiral wound, 10 kDa
MaterialSS316L
Design pressure10 barg
Notes
History
No changes recorded.