Plants
/
Sugar to Hydrogen Peroxide
/ M-1701
M-1701
Ultrafiltration unit
Membrane unit
Open on drawing PID-1701
Data sheet
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. Enzyme is held back by the membrane and returned to
the make-up tank.
2. Clean in place (CIP) connections are not shown.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
SUGAR TO HYDROGEN PEROXIDE
PIPING AND INSTRUMENT DIAGRAM: ENZYME RECOVERY
(ULTRAFILTRATION)
DRAWING NO.
PID-1701
SHEET / REV
7 OF 15 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
M
TK-1701
BROTH HOLD TANK
P-1701
UF FEED PUMP
M-1701
ULTRAFILTRATION UNIT
PID-1601
FROM P-1601
3"-PR-1602-S10
4"-PR-1701-S10
3"-PR-1702-S10
PID-1801
TO E-1801
FV-1703
3"-PR-1703-S10
PID-1301
TO TK-1301
PV-1704
2"-PR-1704-S10
LT
1701
LIC
1701
PDT
1701
0-3 bar
PDI
1701
FT
1703
FIC
1703
PT
1704
PIC
1704
2.5 barg
Design and operating data
Area
420 m2
Type
Spiral wound, 10 kDa
Material
SS316L
Design pressure
10 barg
Connections
Flows in
3"-PR-1702-S10
from P-1701
Flows out
2"-PR-1704-S10
to TK-1301
3"-PR-1703-S10
to E-1801
Instruments
PDT-1701
Differential pressure transmitter
Documents
M-1701 data sheet
Notes
Save note
History
No changes recorded.