TK-1701

Broth hold tank
Agitated tank
1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 A A B B C C D D E E F F NOTES 1. Enzyme is held back by the membrane and returned to the make-up tank. 2. Clean in place (CIP) connections are not shown. INSTRUMENT SYMBOLS Field mounted Control system (DCS), operator can see it Electric signal Main process line Utility / secondary line ENTHRA LABS DEMO DRAWING SUGAR TO HYDROGEN PEROXIDE PIPING AND INSTRUMENT DIAGRAM: ENZYME RECOVERY (ULTRAFILTRATION) DRAWING NO. PID-1701 SHEET / REV 7 OF 15 REV 0 SCALE: NONE DATE: 2026-11-24 FICTIONAL PLANT FOR DEMONSTRATION. NOT FOR CONSTRUCTION. M TK-1701 BROTH HOLD TANK P-1701 UF FEED PUMP M-1701 ULTRAFILTRATION UNIT PID-1601 FROM P-1601 3"-PR-1602-S10 4"-PR-1701-S10 3"-PR-1702-S10 PID-1801 TO E-1801 FV-1703 3"-PR-1703-S10 PID-1301 TO TK-1301 PV-1704 2"-PR-1704-S10 LT 1701 LIC 1701 PDT 1701 0-3 bar PDI 1701 FT 1703 FIC 1703 PT 1704 PIC 1704 2.5 barg
Design and operating data
Capacity120 m3
MaterialSS316L
Design temp60 C
Operating temp30 C
Design pressureATM
Notes
History
No changes recorded.