Sugar to Hydrogen Peroxide
/
PID-2501
Steam and condensate
100%
SVG
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
A
A
B
B
C
C
D
D
E
E
F
F
NOTES
1. Boiler burner management system is a vendor PLC. Flame
loss BSL-2501 closes the gas valve XV-2524.
2. Steam is let down from 10 barg to 3.5 barg by PV-2500.
3. Recovered water from the peroxide column joins the
condensate return.
INSTRUMENT SYMBOLS
Field mounted
Control system (DCS), operator can see it
Electric signal
Main process line
Utility / secondary line
ENTHRA LABS
DEMO DRAWING
SUGAR TO HYDROGEN PEROXIDE
PIPING AND INSTRUMENT DIAGRAM: STEAM AND CONDENSATE
DRAWING NO.
PID-2501
SHEET / REV
15 OF 15 REV 0
SCALE: NONE
DATE: 2026-11-24
FICTIONAL PLANT FOR DEMONSTRATION.
NOT FOR CONSTRUCTION.
B-2501
PACKAGE STEAM BOILER
H-2501
LOW PRESSURE STEAM
HEADER
H-2502
CONDENSATE RETURN
HEADER
TK-2501
CONDENSATE AND FEED
WATER TANK
P-2501
BOILER FEED PUMP
PV-2500
8"-MS-2500-C10
PID-1201
TO E-1201
2"-LS-1201-C10
PID-1801
TO EV-1801
3"-LS-2502-C10
PID-1901
TO E-1902
3"-LS-2503-C10
PID-2101
TO E-2101
2"-LS-2504-C10
PID-2201
TO EV-2201
3"-LS-2505-C10
PID-2301
TO E-2301
2"-LS-2506-C10
PID-1201
FROM E-1201
1"-SC-1201-C10
PID-1801
FROM EV-1801
2"-SC-2512-C10
PID-1901
FROM E-1902
2"-SC-2513-C10
PID-2101
FROM E-2101
1"-SC-2514-C10
PID-2201
FROM EV-2201
2"-SC-2515-C10
PID-2301
FROM E-2301
1"-SC-2516-C10
PID-1901
FROM P-1901
2"-PW-1905-S10
4"-SC-2520-C10
B/L
DEMIN WATER
LV-2521
2"-DW-2521-S10
3"-SC-2522-S10
FV-2523
2"-SC-2523-S10
B/L
NATURAL GAS
S
XV-2524
6"-PG-2524-C10
ATM
PSV-2501
SET 11 barg
PT
2500
PIC
2500
3.5 barg
LT
2501
LIC
2501
LT
2502
LIC
2502
BSL
2501
Scroll to zoom · drag to move · click anything to inspect