Safety Studio

Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
CR-2201 cooling crystalliser
PID-2201 · operating temp 15 C · design pressure ATM · feed about 27 m3/h (quick simulation)
No flowDraft
Causes
  • P-2201 stops
  • FV-2204 fails closed
  • TV-2205 fails closed
  • Hand valve on the inlet left closed
Consequences
  • Downstream of CR-2201 runs short of feed
  • Pumps further on can run dry
  • Quick simulation, P-2201 stopped: 40 lines change flow
Safeguards
  • Level indication LT-2201, LIC-2201
Action
None
More flowDraft
Causes
  • FV-2204 fails open
  • TV-2205 fails open
Consequences
  • CR-2201 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LT-2201, LIC-2201
Action
None
Reverse flowDraft
Causes
  • P-2201 stops while CR-2201 is under pressure
Consequences
  • Back-flow from CR-2201 through the stopped pump
Safeguards
  • Check valve on the pump discharge
Action
None
High levelDraft
Causes
  • HV-220106 left closed
  • Outlet pump stops
Consequences
  • CR-2201 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
  • Level LT-2201, LIC-2201
Action
None
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LT-2201, LIC-2201
Action
None
High temperatureDraft
Causes
  • Cooling water lost or too warm
  • Cooling water control valve fails closed
Consequences
  • CR-2201 overheats
  • Quick simulation, cooling water 5 C warmer: still within limits
Safeguards
  • Temperature control TT-2205, TIC-2205
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • Pump pushing against a closed outlet (3.7 bar at shut-off)
  • External fire
Consequences
  • CR-2201 over its design pressure (ATM)
Safeguards
None on the drawings
Action
  • Check whether CR-2201 needs a relief valve