Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
E-2301 dryer air heater
No flowDraft
Causes
  • B-2301 stops
  • Hand valve on the inlet left closed
Consequences
  • Downstream of E-2301 runs short of feed
  • Quick simulation, B-2301 stopped: 40 lines change flow
Safeguards
None on the drawings
Action
  • Consider a low flow or low level alarm on E-2301
More flowDraft
Causes
  • Upstream pump running faster than normal
Consequences
  • E-2301 cannot keep up (outlet off temperature)
  • Downstream equipment overloaded
Safeguards
None on the drawings
Action
None
Reverse flowDraft
Causes
  • B-2301 stops while E-2301 is under pressure
Consequences
  • Back-flow from E-2301 through the stopped pump
Safeguards
None on the drawings
Action
  • No check valve found after B-2301: add one
High temperatureDraft
Causes
  • Steam control valve fails open
Consequences
  • E-2301 outlet too hot
  • Heat-sensitive product damaged
Safeguards
None on the drawings
Action
  • Add a high temperature alarm on E-2301
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • External fire
Consequences
  • E-2301 over its design pressure (not given)
Safeguards
None on the drawings
Action
  • Check whether E-2301 needs a relief valve