EV-1801 vacuum evaporator
PID-1801 · operating temp 45 C · design pressure FV / 3.5 barg · operating pressure 0.08 bara · feed about 26 m3/h (quick simulation)
No flowDraft
Causes
  • FV-1801 fails closed
  • FV-1810 fails closed
  • Hand valve on the inlet left closed
Consequences
  • Downstream of EV-1801 runs short of feed
  • Pumps further on can run dry
Safeguards
  • Flow control FT-1801, FIC-1801
  • Level indication LT-1801, LIC-1801
Action
None
More flowDraft
Causes
  • FV-1801 fails open
  • FV-1810 fails open
Consequences
  • EV-1801 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LT-1801, LIC-1801
  • Flow control FT-1801, FIC-1801
Action
None
High levelDraft
Causes
  • HV-180104 left closed
  • Outlet pump stops
Consequences
  • EV-1801 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
  • Level LT-1801, LIC-1801
Action
None
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LT-1801, LIC-1801
Action
None
High temperatureDraft
Causes
  • Steam control valve fails open
Consequences
  • EV-1801 outlet too hot
  • Heat-sensitive product damaged
Safeguards
  • Temperature control TT-1801, TIC-1801
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • External fire
Consequences
  • EV-1801 over its design pressure (FV / 3.5 barg)
Safeguards
None on the drawings
Action
  • Check whether EV-1801 needs a relief valve