Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
EV-2201 acid concentrator
PID-2201 · operating pressure 0.2 bara · feed about 10.1 m3/h (quick simulation)
No flowDraft
Causes
  • P-2301 stops
  • LV-2101 fails closed
  • FV-2201 fails closed
  • Hand valve on the inlet left closed
Consequences
  • Downstream of EV-2201 runs short of feed
  • Pumps further on can run dry
  • Quick simulation, P-2301 stopped: 40 lines change flow
Safeguards
None on the drawings
Action
  • Consider a low flow or low level alarm on EV-2201
More flowDraft
Causes
  • LV-2101 fails open
  • FV-2201 fails open
Consequences
  • EV-2201 overfills
  • Downstream equipment overloaded
Safeguards
None on the drawings
Action
  • Add a high level alarm on EV-2201
Reverse flowDraft
Causes
  • P-2301 stops while EV-2201 is under pressure
Consequences
  • Back-flow from EV-2201 through the stopped pump
Safeguards
  • Check valve on the pump discharge
Action
None
High levelDraft
Causes
  • HV-220104 left closed
  • Outlet pump stops
Consequences
  • EV-2201 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
None on the drawings
Action
  • No level measurement on EV-2201: add a level transmitter with high alarm
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
None on the drawings
Action
  • Add a low level trip to protect the outlet pump of EV-2201
High temperatureDraft
Causes
  • Steam control valve fails open
Consequences
  • EV-2201 outlet too hot
  • Heat-sensitive product damaged
Safeguards
None on the drawings
Action
  • Add a high temperature alarm on EV-2201
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • Pump pushing against a closed outlet (3.7 bar at shut-off)
  • External fire
Consequences
  • EV-2201 over its design pressure (not given)
Safeguards
  • Pressure control PT-2201, PIC-2201
Action
  • Check whether EV-2201 needs a relief valve