Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
F-1401 inlet air filter
No flowDraft
Causes
  • Hand valve on the inlet left closed
Consequences
  • Downstream of F-1401 runs short of feed
  • Pumps further on can run dry
Safeguards
None on the drawings
Action
  • Consider a low flow or low level alarm on F-1401
More flowDraft
Causes
  • Upstream pump running faster than normal
Consequences
  • F-1401 overfills
  • Downstream equipment overloaded
Safeguards
None on the drawings
Action
  • Add a high level alarm on F-1401
High levelDraft
Causes
  • Outlet pump stops
Consequences
  • F-1401 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
None on the drawings
Action
  • No level measurement on F-1401: add a level transmitter with high alarm
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
None on the drawings
Action
  • Add a low level trip to protect the outlet pump of F-1401
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • External fire
Consequences
  • F-1401 over its design pressure (not given)
Safeguards
  • Pressure control PDT-1401
Action
  • Check whether F-1401 needs a relief valve