M-1701 ultrafiltration unit
PID-1701 · design pressure 10 barg · feed about 27.3 m3/h (quick simulation)
No flowDraft
Causes
  • P-1701 stops
  • Hand valve on the inlet left closed
Consequences
  • Downstream of M-1701 runs short of feed
  • Quick simulation, P-1701 stopped: 40 lines change flow
Safeguards
  • Flow control FT-1703, FIC-1703
Action
None
More flowDraft
Causes
  • Upstream pump running faster than normal
Consequences
  • M-1701 overfills
  • Downstream equipment overloaded
Safeguards
  • Flow control FT-1703, FIC-1703
Action
None
Reverse flowDraft
Causes
  • P-1701 stops while M-1701 is under pressure
Consequences
  • Back-flow from M-1701 through the stopped pump
Safeguards
  • Check valve on the pump discharge
Action
None
High levelDraft
Causes
  • PV-1704 fails closed
  • FV-1703 fails closed
  • HV-130103 left closed
  • HV-170106 left closed
  • Outlet pump stops
Consequences
  • M-1701 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
None on the drawings
Action
  • No level measurement on M-1701: add a level transmitter with high alarm
Low levelDraft
Causes
  • PV-1704 fails open
  • FV-1703 fails open
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
None on the drawings
Action
  • Add a low level trip to protect the outlet pump of M-1701
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • Pump pushing against a closed outlet (6.7 bar at shut-off)
  • External fire
Consequences
  • M-1701 over its design pressure (10 barg)
Safeguards
  • Pressure control PDT-1701, PDI-1701
Action
  • Check whether M-1701 needs a relief valve