Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
R-1501 enzyme reactor 1
PID-1501 · design temp 60 C · operating temp 30 C · design pressure 3.5 barg · operating pressure 1.5 barg · feed about 62.1 m3/h (quick simulation)
No flowDraft
Causes
  • P-1301 stops
  • P-1302 stops
  • FV-1205 fails closed
  • AV-1502 fails closed
  • FV-1503 fails closed
  • TV-1501 fails closed
  • Hand valve on the inlet left closed
Consequences
  • Downstream of R-1501 runs short of feed
  • Pumps further on can run dry
  • Quick simulation, P-1301 stopped: 40 lines change flow
Safeguards
  • Flow control FT-1205, FIC-1205, FT-1503, FIC-1503
  • Level indication LT-1501, LIC-1501
Action
None
More flowDraft
Causes
  • FV-1205 fails open
  • AV-1502 fails open
  • FV-1503 fails open
  • TV-1501 fails open
Consequences
  • R-1501 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LT-1501, LIC-1501
  • Flow control FT-1205, FIC-1205, FT-1503, FIC-1503
Action
None
Reverse flowDraft
Causes
  • P-1301 stops while R-1501 is under pressure
  • P-1302 stops while R-1501 is under pressure
Consequences
  • Back-flow from R-1501 through the stopped pump
Safeguards
  • Check valve on the pump discharge
Action
None
High levelDraft
Causes
  • HV-150103 left closed
  • Outlet pump stops
Consequences
  • R-1501 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
  • Level LT-1501, LIC-1501
  • Relief PSV-1501
Action
None
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LT-1501, LIC-1501
Action
None
High temperatureDraft
Causes
  • Cooling water lost or too warm
  • Cooling water control valve fails closed
  • Reaction runs faster than planned
Consequences
  • R-1501 overheats
  • Product spoils or decomposes
  • Quick simulation, cooling water 5 C warmer: R-1501 cooling at 937% of what the water can take
Safeguards
  • Temperature control TT-1501, TIC-1501
  • Relief PSV-1501
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • Pump pushing against a closed outlet (7.4 bar at shut-off)
  • External fire
Consequences
  • R-1501 over its design pressure (3.5 barg)
Safeguards
  • Relief PSV-1501 set 3.5 barg
Action
None