Safety Studio

Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
SI-2301 product silo
PID-2301 · · feed about 1.6 m3/h (quick simulation)
No flowDraft
Causes
  • Hand valve on the inlet left closed
Consequences
  • Downstream of SI-2301 runs short of feed
Safeguards
  • Level indication LT-2302, LI-2302
Action
None
More flowDraft
Causes
  • Upstream pump running faster than normal
Consequences
  • SI-2301 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LT-2302, LI-2302
Action
None
High levelDraft
Causes
  • HV-230104 left closed
  • Outlet pump stops
Consequences
  • SI-2301 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
  • Level LT-2302, LI-2302
Action
None
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LT-2302, LI-2302
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • External fire
Consequences
  • SI-2301 over its design pressure (not given)
Safeguards
None on the drawings
Action
  • Check whether SI-2301 needs a relief valve