Safety Studio

Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
TK-1201 feed mix tank
PID-1201 · design temp 90 C · operating temp 40 C · design pressure ATM · feed about 24.5 m3/h (quick simulation)
No flowDraft
Causes
  • P-1101A stops
  • P-1101B stops
  • FV-1201 fails closed
  • Hand valve on the inlet left closed
Consequences
  • Downstream of TK-1201 runs short of feed
  • Pumps further on can run dry
  • Quick simulation, P-1101A stopped: 40 lines change flow
Safeguards
  • Level indication LT-1201, LIC-1201
Action
None
More flowDraft
Causes
  • FV-1201 fails open
Consequences
  • TK-1201 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LT-1201, LIC-1201
Action
None
Reverse flowDraft
Causes
  • P-1101A stops while TK-1201 is under pressure
  • P-1101B stops while TK-1201 is under pressure
Consequences
  • Back-flow from TK-1201 through the stopped pump
Safeguards
  • Check valve on the pump discharge
Action
None
High levelDraft
Causes
  • HV-120104 left closed
  • Outlet pump stops
Consequences
  • TK-1201 overflows or liquid goes into the vent
  • Spill of glucose solution, 25 wt%
Safeguards
  • Level LT-1201, LIC-1201
Action
None
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LT-1201, LIC-1201
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • Pump pushing against a closed outlet (4.3 bar at shut-off)
  • External fire
Consequences
  • TK-1201 over its design pressure (ATM)
Safeguards
None on the drawings
Action
None