TK-2101 oxidation feed tank
PID-2101 · design temp 80 C · design pressure ATM · feed about 14.6 m3/h (quick simulation)
No flowDraft
Causes
  • P-1801 stops
  • LV-1801 fails closed
  • Hand valve on the inlet left closed
Consequences
  • Downstream of TK-2101 runs short of feed
  • Pumps further on can run dry
  • Quick simulation, P-1801 stopped: 40 lines change flow
Safeguards
  • Level indication LT-2101, LIC-2101
Action
None
More flowDraft
Causes
  • LV-1801 fails open
Consequences
  • TK-2101 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LT-2101, LIC-2101
Action
None
Reverse flowDraft
Causes
  • P-1801 stops while TK-2101 is under pressure
Consequences
  • Back-flow from TK-2101 through the stopped pump
Safeguards
  • Check valve on the pump discharge
Action
None
High levelDraft
Causes
  • HV-210102 left closed
  • Outlet pump stops
Consequences
  • TK-2101 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
  • Level LT-2101, LIC-2101
Action
None
Low levelDraft
Causes
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LT-2101, LIC-2101
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • Pump pushing against a closed outlet (5.5 bar at shut-off)
  • External fire
Consequences
  • TK-2101 over its design pressure (ATM)
Safeguards
None on the drawings
Action
None