Safety Studio

Prepares the HAZOP from the drawings and checks the relief valves. It saves prep time; the team still runs the review and signs off every row. Legal responsibility for safety stays with the plant.

HAZOP ExcelCSV
V-1401 air knockout drum
PID-1401 · design temp 80 C · design pressure 7 barg
No flowDraft
Causes
  • Hand valve on the inlet left closed
Consequences
  • Downstream of V-1401 runs short of feed
Safeguards
  • Level indication LSH-1401, LY-1401
Action
None
More flowDraft
Causes
  • Upstream pump running faster than normal
Consequences
  • V-1401 overfills
  • Downstream equipment overloaded
Safeguards
  • Level control LSH-1401, LY-1401
Action
None
High levelDraft
Causes
  • LV-1401 fails closed
  • Outlet pump stops
Consequences
  • V-1401 overflows or liquid goes into the vent
  • Spill of process liquid
Safeguards
  • Level LSH-1401, LY-1401
Action
None
Low levelDraft
Causes
  • LV-1401 fails open
  • Feed stops
Consequences
  • Outlet pump runs dry and is damaged
Safeguards
  • Level LSH-1401, LY-1401
Action
None
High pressureDraft
Causes
  • Outlet blocked (valve closed)
  • External fire
Consequences
  • V-1401 over its design pressure (7 barg)
Safeguards
None on the drawings
Action
  • Check whether V-1401 needs a relief valve